-
Similar searches
Services
-
Cafeteria & Food Services
Includes the preparation and offering of food and beverage items, waste management, and the ongoing management of the cafeteria space.
-
Meeting & Conference Services
Includes all activities related to planning and executing meetings or conferences.
Products
-
Awards and Plaques
Government agencies purchase millions of dollars’ worth of awards and plaques each year for awards programs, recognition ceremonies and other initiatives. Recovered-content awards are generally made f...
Categories:
Non-Paper Office Products- CPG
-
Bike Racks
Bike racks provide a method for cyclists to secure their bicycles safely. Commonly found in public areas, bike racks can be designed to hold 1 to 50 bicycles and can be free standing units, anchored b...
Categories:
Park and Recreation- CPG
(25-30% recovered steel; including 16% postconsumer content)
-
Binders
A loose-leaf binder contains split metal rings attached to a metal back that hold perforated sheets of paper. Chipboard, pressboard, plastic-covered chipboard or paperboard, cloth-covered chipboard or...
Categories:
Non-Paper Office Products- CPG
-
Building Insulation
Insulation made from recovered materials is available for thermal insulating applications. The product is available in several forms including rolls, loose-fill and spray foam. Insulation also can inc...
Categories:
Construction Materials- CPG
- BioPreferred Program - Federal Purchasing
-
Carpet
Floor coverings composed of woven, tufted, or knitted fiber and a backing system.
Categories:
Building Finishes- CPG
- BioPreferred Program - Federal Purchasing
- BioPreferred Program - USDA Certified Biobased
-
Carpet Cushion
A cushion or padding that is placed underneath carpet to minimize stress on flooring, reduce noise, minimize stains to the sub-floor, and increase cushion for the feet.
Categories:
Building Finishes- CPG
-
Cement and Concrete
Cement and concrete are materials used to build strong, hard surfaces and structures. Cement is a powder of alumina, silica, lime, iron oxide, and magnesium oxide that is mixed with water to produce c...
- CPG
-
Channelizers
Channelizers are barrels or drums that direct traffic around areas of road repair or construction. Channelizers are designed and colored to be highly visible and can be constructed from recovered high...
Categories:
Traffic Control- CPG
-
Composite Panels
Engineered products designed for use in structural walls, curtain walls, floors and flat roofs in commercial buildings.
Categories:
Building Finishes- BioPreferred Program - Federal Purchasing
-
Compost
Decayed organic material used as a plant fertilizer.
Categories:
Landscaping Products- BioPreferred Program - Federal Purchasing
- CPG
-
Floor Tiles (Heavy Duty/Commercial)
Floor tiles for heavy duty or commercial specialty applications can contain up to 100 percent postconsumer rubber. They are made from used truck and airline tires.
Categories:
Building Finishes- CPG
-
Floor Tiles
Products, other than carpet products, that are designed for use as the top layer on a floor. Examples are bamboo, hardwood, and cork tiles.
Categories:
Building Finishes- CPG
-
Mats
Mats are temporary or semipermanent protective floor coverings used for numerous applications including protecting carpet from wear and tear or providing traction on stairs or slippery floors.
Categories:
Building Finishes- CPG
-
Office Furniture Components
Materials used in office furniture manufacturing include polyethylene terephthalate (PET) in fabrics; plastic, which is integrated in components such as laminated work surfaces and arm rests; aluminum...
Categories:
Building Furnishings- CPG
-
Structural Fiberboard
Structural fiberboard is a panel made from wood, cane or paper fibers matted together which is used for sheathing, structural and insulating purposes. Examples include building board, insulating formb...
- Federal Programs
- CPG
- (80-100% recovered wood waste, bagasse, and paper)
- BioPreferred Program - Federal Purchasing
- (94% minimum biobased content)
- EPA Recommended Specifications, Standards, and Ecolabels
- Cradle to Cradle Certified
- SCS Indoor Advantage Gold
- EcoLogo/UL 2818 GREENGUARD Certification
- SpecificationIndoor Air Quality/VOC Emissions: Products shall meet the California Department of Public Health (CDPH) Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers, Version 1.1-2010. (This is the VOC emission testing method for California Specification 01350.)
- For information about these standards, please go to EPA’s Recommendations website.
-
Blends
Categories:
Building Finishes- CPG
- (100% postconsumer rubber/plastic composite)
- BioPreferred Program - Federal Purchasing
- (23% minimum biobased content)
-
Bonded Polyurethane
Categories:
Building Finishes- CPG
- (15-50% old carpet cushion; including 15-50% postconsumer content)
-
Cellulose Loose-Fill and Spray-On
Categories:
Building Furnishings- CPG
- (75% postconsumer paper)
-
Fabric
Categories:
Building Furnishings- CPG
- (100% postconsumer polyethylene terephthalate)
-
Furniture Structure
Categories:
Building Furnishings- CPG
- (75-100% recovered aluminum)
-
Jute
Categories:
Building Finishes- CPG
- (40% postconsumer burlap)
-
Particleboard/Fiberboard Component
Categories:
Building Furnishings- CPG
- (100% recovered agricultural fiber)
- (80-100% recovered wood or wood composite)
-
Plastic
Categories:
Building Finishes- Federal Programs
- BioPreferred Program - Federal Purchasing
- BioPreferred Program - USDA Certified Biobased
- CPG
- (90-100% recovered plastic)
- EPA Recommended Specifications, Standards, and Ecolabels
- Non-Federal Multi-Attribute Standards and Ecolabels
- Cradle to Cradle Certified
- NSF/ANSI 332
- GECA Floor Coverings
- TCNA: ANSI A138.1/Green Squared
- If the above are not available:
- International Living Future Institute: Living Product Challenge 1.0
- Sustainable Materials Rating Technology (SMaRT)
- Non-Federal Single Attribute Standards and Ecolabels
- International Living Future Institute: Declare
- FloorScore
- SCS Indoor Advantage Gold
- EcoLogo/UL 2818 GREENGUARD Certification
- Global Recycled Standard
- Specification
Indoor Air Quality/VOC Emissions: Products shall meet the California Department of Public Health (CDPH) Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers, Version 1.1-2010. (This is the VOC emission testing method for California Specification 01350.)
- For information about these standards, please go to EPA’s Recommendations website.
-
Plastic
Categories:
Building Finishes- CPG
- 100% recovered plastic; including 10-100% postconsumer content
- BioPreferred Program - Federal Purchasing
- (23% minimum biobased content)
-
Plastic Furniture Component
Categories:
Building Furnishings- CPG
- (95% recovered high density polyethylene; including 70-75% postconsumer content)
-
Polyester Carpet Face Fiber
Categories:
Building Finishes- Federal Programs
- BioPreferred Program - Federal Purchasing
- (7% minimum biobased content)
- BioPreferred Program - USDA Certified Biobased
- CPG
- (25-100% recovered polyethylene terephthalate; including 25-100% postconsumer content)
- EPA Recommended Specifications, Standards, and Ecolabels
- Non-Federal Multi-Attribute Standards and Ecolabels
- Cradle to Cradle Certified
- GECA Floor Coverings
- NSF 140
- If the above are not available:
- Environmental Choice New Zealand: Carpets
- International Living Future Institute: Living Product Challenge 1.0
- Sustainable Materials Rating Technology (SMaRT)
- Non-Federal Single Attribute Standards and Ecolabels
- International Living Future Institute: Declare
- SCS Indoor Advantage Gold
- EcoLogo/UL 2818 GREENGUARD Certification
- Global Recycled Standard
- CRI Green Label PlusTM Program1*
- SpecificationIndoor Air Quality/VOC Emissions: Products shall meet the California Department of Public Health (CDPH) Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers, Version 1.1-2010. (This is the VOC emission testing method for California Specification 01350.)
- For information about these standards, please go to EPA’s Recommendations website.
-
Remanufactured or Refurbished Furniture
Categories:
Building Furnishings- CPG
- (25-75% recovered material; including 25-75% postconsumer content)
-
Rubber
Categories:
Building Finishes- CPG
- (60-90% recovered tire rubber; including 60-90% postconsumer content)
-
Rubber
Categories:
Building Finishes- Federal Programs
- BioPreferred Program - Federal Purchasing
- BioPreferred Program - USDA Certified Biobased
- CPG
- (90-100% postconsumer rubber)
- EPA Recommended Specifications, Standards, and Ecolabels
- Non-Federal Multi-Attribute Standards and Ecolabels
- Cradle to Cradle Certified
- NSF/ANSI 332
- GECA Floor Coverings
- TCNA: ANSI A138.1/Green Squared
- If the above are not available:
- International Living Future Institute: Living Product Challenge 1.0
- Sustainable Materials Rating Technology (SMaRT)
- Non-Federal Single Attribute Standards and Ecolabels
- International Living Future Institute: Declare
- FloorScore
- SCS Indoor Advantage Gold
- EcoLogo/UL 2818 GREENGUARD Certification
- Global Recycled Standard
- Specification
Indoor Air Quality/VOC Emissions: Products shall meet the California Department of Public Health (CDPH) Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers, Version 1.1-2010. (This is the VOC emission testing method for California Specification 01350.)
- For information about these standards, please go to EPA’s Recommendations website.
-
Rubber
Categories:
Building Finishes- CPG
- (85-100% recovered rubber; including 75-100% postconsumer content)
- BioPreferred Program - Federal Purchasing
- (23% minimum biobased content)
-
Synthetic Fibers
Categories:
Building Finishes- CPG
- (100% recovered carpet fabrication scrap)
-
Woven, Tufted, or Knitted Fiber and a Backing System
Categories:
Building Finishes- BioPreferred Program - Federal Purchasing
- (7% minimum biobased content)
- BioPreferred Program - USDA Certified Biobased
-
Paint
Reprocessed paint is postconsumer latex paint that has been sorted by a variety of characteristics including type (i.e., interior or exterior), light and dark colors, and finish (e.g., high-gloss or f...
Categories:
Building Finishes- BioPreferred Program - Federal Purchasing
- CPG
-
Consolidated Latex Paint
Categories:
Building Finishes- BioPreferred Program - Federal Purchasing
- BioPreferred Program - USDA Certified Biobased
- CPG
- (100% postconsumer content)
-
Reprocessed Latex Paint -- Dark Colors
Categories:
Building Finishes- Federal Programs
- BioPreferred Program - Federal Purchasing
- BioPreferred Program - USDA Certified Biobased
- CPG
- (50 - 99% recovered material, including 50 - 99% postconsumer material)
- EPA Recommended Specifications, Standards, and Ecolabels
- Non-Federal Multi-Attribute Standards and Ecolabels
- Cradle to Cradle Certified
- GECA Paints & Coatings
- Green Seal 11
- Green Seal 43
- MPI Extreme Green
- If the above are not available:
- Environmental Choice New Zealand: Paints
- International Living Future Institute: Living Product Challenge 1.0
- Sustainable Materials Rating Technology (SMaRT)
- Non-Federal Single Attribute Standards and Ecolabels
- International Living Future Institute: Declare
- SCS Indoor Advantage Gold
- EcoLogo/UL 2818 GREENGUARD Certification
- SpecificationIndoor Air Quality/VOC Emissions: Products shall meet the California Department of Public Health (CDPH) Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers, Version 1.1-2010. (This is the VOC emission testing method for California Specification 01350.)
- For information about these standards, please go to EPA’s Recommendations website.
-
Reprocessed Latex Paint -- White, Off-White, and Pastel Colors
Categories:
Building Finishes- Federal Programs
- BioPreferred Program - Federal Purchasing
- BioPreferred Program - USDA Certified Biobased
- CPG
- (20% postconsumer material)
- EPA Recommended Specifications, Standards, and Ecolabels
- Non-Federal Multi-Attribute Standards and Ecolabels
- Cradle to Cradle Certified
- GECA Paints & Coatings
- Green Seal 11
- Green Seal 43
- MPI Extreme Green
- If the above are not available:
- Environmental Choice New Zealand: Paints
- International Living Future Institute: Living Product Challenge 1.0
- Sustainable Materials Rating Technology (SMaRT)
- Non-Federal Single Attribute Standards and Ecolabels
- International Living Future Institute: Declare
- SCS Indoor Advantage Gold
- EcoLogo/UL 2818 GREENGUARD Certification
- SpecificationIndoor Air Quality/VOC Emissions: Products shall meet the California Department of Public Health (CDPH) Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers, Version 1.1-2010. (This is the VOC emission testing method for California Specification 01350.)
- For information about these standards, please go to EPA’s Recommendations website.
-
Interior Paints and Coatings -- Latex
Categories:
Building Finishes- Federal Programs
- BioPreferred Program - Federal Purchasing
- (20% minimum biobased content)
- BioPreferred Program - USDA Certified Biobased
- CPG
- (See Reprocessed latex paint listings for recycled content recommendations)
- EPA Recommended Specifications, Standards, and Ecolabels
- Non-Federal Multi-Attribute Standards and Ecolabels
- Cradle to Cradle Certified
- GECA Paints & Coatings
- Green Seal 11
- Green Seal 43
- MPI Extreme Green
- If the above are not available:
- Environmental Choice New Zealand: Paints
- International Living Future Institute: Living Product Challenge 1.0
- Sustainable Materials Rating Technology (SMaRT)
- Non-Federal Single Attribute Standards and Ecolabels
- International Living Future Institute: Declare
- SCS Indoor Advantage Gold
- EcoLogo/UL 2818 GREENGUARD Certification
- SpecificationIndoor Air Quality/VOC Emissions: Products shall meet the California Department of Public Health (CDPH) Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers, Version 1.1-2010. (This is the VOC emission testing method for California Specification 01350.)
- For information about these standards, please go to EPA’s Recommendations website.
-
Interior Paints and Coatings -- Water-borne Alkyd
Categories:
Building Finishes- BioPreferred Program - Federal Purchasing
- (20% minimum biobased content)
-
Interior Paints and Coatings -- Oil-Based
Categories:
Building Finishes- BioPreferred Program - Federal Purchasing
- (67% minimum biobased content)
-
Interior Paints and Coatings -- Solvent-borne Alkyd
Categories:
Building Finishes- BioPreferred Program - Federal Purchasing
- (67% minimum biobased content)
-
Plastic
Categories:
Building Finishes- Federal Programs
- BioPreferred Program - Federal Purchasing
- BioPreferred Program - USDA Certified Biobased
- CPG
- (90-100% recovered plastic)
- EPA Recommended Specifications, Standards, and Ecolabels
- Non-Federal Multi-Attribute Standards and Ecolabels
- Cradle to Cradle Certified
- NSF/ANSI 332
- GECA Floor Coverings
- GreenCircle Certified Environmental Facts for Flooring Products
- TCNA: ANSI A138.1/Green Squared
- If the above are not available:
- International Living Future Institute: Living Product Challenge 1.0
- Sustainable Materials Rating Technology (SMaRT)
- Non-Federal Single Attribute Standards and Ecolabels
- International Living Future Institute: Declare
- FloorScore
- SCS Indoor Advantage Gold
- EcoLogo/UL 2818 GREENGUARD Certification
- Global Recycled Standard
- SpecificationIndoor Air Quality/VOC Emissions: Products shall meet the California Department of Public Health (CDPH) Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers, Version 1.1-2010. (This is the VOC emission testing method for California Specification 01350.)
- For information about these standards, please go to EPA’s Recommendations website.
-
Rubber
Categories:
Building Finishes- Federal Programs
- BioPreferred Program - Federal Purchasing
- BioPreferred Program - USDA Certified Biobased
- CPG
- (90-100% postconsumer rubber)
- EPA Recommended Specifications, Standards, and Ecolabels
- Non-Federal Multi-Attribute Standards and Ecolabels
- Cradle to Cradle Certified
- GECA Floor Coverings
- GreenCircle Certified Environmental Facts for Flooring Products
- NSF/ANSI 332
- TCNA: ANSI A138.1/Green Squared
- If the above are not available:
- International Living Future Institute: Living Product Challenge 1.0
- Sustainable Materials Rating Technology (SMaRT)
- Non-Federal Single Attribute Standards and Ecolabels
- International Living Future Institute: Declare
- FloorScore
- SCS Indoor Advantage Gold
- EcoLogo/UL 2818 GREENGUARD Certification
- Global Recycled Standard
- SpecificationIndoor Air Quality/VOC Emissions: Products shall meet the California Department of Public Health (CDPH) Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers, Version 1.1-2010. (This is the VOC emission testing method for California Specification 01350.)
- For information about these standards, please go to EPA’s Recommendations website.
-
100% Recycled Content Copier Paper
A lightweight paper used for photocopying that consists of 100% recycled materials.
Categories:
Paper Office Products- BioPreferred Program - USDA Certified Biobased
- CPG
- This meets and exceeds the CPG minimum content of 30% postconsumer fiber.
-
Nylon
Categories:
Building Finishes- Federal Programs
- BioPreferred Program - Federal Purchasing
- (7% minimum biobased content)
- BioPreferred Program - USDA Certified Biobased
- EPA Recommended Specifications, Standards, and Ecolabels
- Non-Federal Multi-Attribute Standards and Ecolabels
- Cradle to Cradle Certified
- If the above are not available:
- GECA Floor Coverings
- GreenCircle Certified Environmental Facts for Flooring Products
- NSF 140
- Environmental Choice New Zealand: Carpets
- Sustainable Materials Rating Technology (SMaRT)
- Non-Federal Single Attribute Standards and Ecolabels
- International Living Future Institute: Living Product Challenge 1.0
- International Living Future Institute: Declare
- SCS Indoor Advantage Gold
- EcoLogo/UL 2818 GREENGUARD Certification
- Global Recycled Standard
- CRI Green Label PlusTM Program1*
- SpecificationIndoor Air Quality/VOC Emissions: Products shall meet the California Department of Public Health (CDPH) Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers, Version 1.1-2010. (This is the VOC emission testing method for California Specification 01350.)
- For information about these standards, please go to EPA’s Recommendations website.
-
Furniture
Office furniture includes seating, desks, storage units, file cabinets, tables and systems furniture (or "cubicles") used in virtually all federal offices. Most office furniture is made of wood or ste...
Categories:
Building Furnishings- Federal Programs
- CPG
- (see Office Furniture Components)
- BioPreferred Program - USDA Certified Biobased
- EPA Recommended Specifications, Standards, and Ecolabels
- Non-Federal, Multi-Attribute Standards and Ecolabels
- ANSI/BIFMA e3-2014e
- Cradle to Cradle Certified
- GECA Furniture, Fittings, and Foam
- TUV Rheinland Green Product Mark
- If the above are not available:
- International Living Future Institute: Living Product Challenge 1.0
- Sustainable Furnishings Council Exemplary
- Sustainable Materials Rating Technology (SMaRT)
- Non-Federal, Single Attribute/Single Material Standards and Ecolabels
- International Living Future Institute: Declare
- SCS Indoor Advantage Gold
- EcoLogo/UL 2818 GREENGUARD Certification
- Global Recycled Standard
- NSF/ANSI 336
- SpecificationHazardous Flame Retardents: Upholstered products shall meet Technical Bulletin 117-2013 (California’s furniture flammability standard) and must comply with the labeling requirements of California Senate Bill 1019, which was passed on September 30, 2014, and requires a label indicating whether the product contains or does not contain added Flame Retardants.
Indoor Air Quality/VOC Emissions: Products shall meet ANSI/BIFMA X7.1 Standard for Formaldehyde and TVOC Emissions, or equivalent.
Note: Beginning December 2017, products shall instead meet the emissions requirements of BIFMA e3 criterion 7.6.2, or equivalent.
- For information about these standards, please go to EPA’s Recommendations website.
-
Exterior Paint and Coatings
Categories:
Building FinishesFederal Programs
- BioPreferred Program - Federal Purchasing
(83% biobased content)